Sitka's Structural Design Criteria
(For use with the International Building Code 2006 or the American Society
of Civil Engineers - Minimum Design Loads for Buildings and Other Structures
ASCE 7-05.)
- Wind Load:
Basic wind speed, V (3-second gust wind speed) = 120 miles per hour
- Snow Load:
Ground snow load, pg = 50 pounds per square foot
- Earthquake Load:
Maximum considered earthquake ground motion-
0.2 second spectral response, Ss = 0.97 g
1.0 second spectral response, S1 = 0.50 g
- Frost Depth:
Minimum of 18 inches required from finish grade to base of footing or base of non-frost susceptible fill.
- Wind Exposure Definitions
Codes in effect in Sitka:
Residential (set by Sitka General Code):
- 2006 International Residential Code
Commercial (set by State regulation)
- 2006 International Building, Fire, and Mechanical Codes
- 2006 Uniform Plumbing Code
- 2008 National Electric Code